90 Minute Positive Pressure
|
1 3/4” thick
|
|
Door Sizes
|
Min.
|
Max
|
|
•
Single Door (W x H)
|
-
|
3'6" x 8'
|
|
•
Door Pairs (W x H)
|
-
|
7' x 8'
|
|
•
Door Thickness
|
1 ¾”
|
|
Dimensional Restrictions
|
Min.
|
Max.
|
|
•
Stiles
|
5"
|
-
|
|
•
Top Rail
|
5"
|
-
|
|
•
Bottom Rail
|
5”
|
-
|
|
•
Center Rails & Mullions
|
3.625"
|
-
|
|
•
Panel Width
|
6”
|
-
|
|
•
Panel Height
|
6”
|
-
|
|
Sticking Options
|
|
•
Ovolo, Ogee, Mission,
& Square
|
|
• Ogee sticking looks very similar to Ovolo due to small size of the molding.
|
|
Panel Options
|
|
•
Raised, Flat, Step, & Rimband Step
|
|
•
Pairs-Flat panel size=1.0625”; Raised panel size=1.71875”
|
|
•
Single-Flat panel size=.8125”; Raised panel size=1.5”
|
|
Glass Options
|
|
•
No glass allowed
|
|
Machining Restrictions
|
|
•
Must have positive latching hardware
|
|
•
No concealed vertical rod exit device
|
|
•
No double egress pairs
|
|
•
No raceways
|
|
•
Arched panel doors are allowed (A or L doors)
(No arch door are allowed- AA doors)
(No radius doors are allowed – R or RR
doors)
|
|
• Auto Door Bottom can be surface or
mortised
|
|
V-Groove on panels
|
|
Raised panels
|
Flat panels
|
|
Yes
|
Yes
|
|
Face molding is OK on
this
|
|
|
|
|
|
90 Minute Positive Pressure
|
2 1/4” thick
|
|
Door Sizes
|
Min.
|
Max
|
|
•
Single Door (W x H)
|
-
|
3'6" x 8'
|
|
•
Door Pairs (W x H)
|
-
|
7' x 8'
|
|
•
Door Thickness
|
2-1/4"
|
|
Dimensional Restrictions
|
Min.
|
Max.
|
|
•
Stiles
|
5"
|
-
|
|
•
Top Rail
|
5"
|
-
|
|
•
Bottom Rail
|
8-1/2"
|
-
|
|
•
Center Rails & Mullions
|
4"
|
-
|
|
•
Panel Width
|
6-1/8"
|
32"
|
|
•
Panel Height
|
9-3/8"
|
46-3/4"
|
|
Sticking Options
|
|
•
Ovolo, Ogee, Mission,
& Square
|
|
Panel Options
|
|
•
Raised, Flat, Step, & Rimband Step
|
|
•
Flat panel size=1.25”; Raised panel size=1.5”
|
|
Glass Options
|
|
•
No glass allowed
|
|
Machining Restrictions
|
|
•
Must have positive latching hardware
|
|
•
No concealed vertical rod exit device
|
|
•
No double egress pairs
|
|
•
No raceways
|
|
•
Arched panel doors are allowed (A or L doors)
(No arch door are allowed- AA doors)
(No radius doors are allowed – R or RR
doors)
|
|
• Surface auto door bottom only
|
|
V-Groove on panels
|
|
Raised panels
|
Flat panels
|
|
Not available
|
Not available
|
|
Face molding is OK on
this
|
|
|
|
|
|
| *Rules Per Intertek Report 3070697 |
| Rule #1 Lock rail may be moved +/- 10" above or below 40" standard latch point. |
| As long as: |
| • Maximum Panel Size is not to be exceeded |
| • Must maintain 1-1/2" of unaltered material from panel cutout to lock cutout |
| • Increased Stile Width may be necessary |
| Rule #2 Lock Rail can be replaced by 2 or more Intermediate Rails |
| As long as: |
| • Maximum Panel Size is not to be exceeded |
| • Must maintain 1-1/2" of material from panel cutout to lock cutout |
| • Increased Stile Width may be necessary |
| Evaluated and in Compliance with the following Standards: |
| • UBC 7-2 (1997) Part 1 Testing Standards for Swinging Fire Doors |
| • UL 10C (1998) Fire Tests of Door Assemblies - Positive Pressure |
| • NFPA 252 (1999) Standard Methods for Fire Tests of Door Assemblies |
| • CAN4-S104 (1985) Standard Methods of Fire Tests of Door Assemblies |
20-Min Positive |
20-Min Neutral |
45-Min Positive |
60-Min Positive |
90-Min Positive
|